Water systems testing

Water supply systems inside buildings: hot and cold water systems. Testing of water quality and Legionella spp.

Systems
hot and cold water
Testing
Legionella spp.
Frequency
per buildingrisk assessment

When to test for Legionella?

Besides regular testing, we also recommend it in these situations.

Regulation NN 43/24 (in Croatian) (opens in a new tab)
  • Every building

    has its own testing plan

    The frequency is set by the risk assessment.

  • Positive or failed result
  • Works or disinfection
  • Start of season or downtime
  • New building or new use
  • Poor temperature or circulation
  • Suspected legionellosis

What is tested

From the boiler room to the tap: we take the samples, the laboratory does the analysis.

  1. We sample in the building

    hot and cold water, points of use

  2. We take it to the lab

    NZZJZPGŽ

  3. We send you the results

    with an assessment of compliance with the regulations

A hand pointing at a controller in a plant room: redox 785 mV, 18 °C, pH 7.2

Water systems · hot and cold waterLegionella and group A

Legionella spp.hot water

  • Buildings with central hot water
  • Hotels, campsites and similar
  • Water temperature measured on site

Samplesafter flushing

  • Cold water where it enters the building
  • Hot water leaving the tank
  • Hot water at the farthest point
  • Hotels: two more from the end risers

Water qualityas for drinking water

  • Water quality parameters (group A)
All parameters: Drinking water

Occupancy permittechnical inspection

  • Group A and hydrocarbons (C10–C40)
  • New builds and renovations

You get a test report for every sample

For each parameter, the report gives the test method, the maximum permitted value, the result and an assessment of compliance with the regulations.

Water systems: LegionellaHotel, hot water system
ParameterLimit
At the sampling point
Hot water temperature · farthest pointthermometer≥ 50 °C
Laboratory
Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols. · cold water, inletHRN EN ISO 11731< 100 cfu/L
Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols. · tank outletHRN EN ISO 11731< 100 cfu/L
Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols. · farthest pointHRN EN ISO 11731< 100 cfu/L
Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols. · end riser 1HRN EN ISO 11731< 100 cfu/L
Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols. · end riser 2HRN EN ISO 11731< 100 cfu/L

Legionella spp.: limit of negligible contamination under the Croatian regulations (NN 43/24)

Contract partnerTeaching Institute of Public Healthof Primorje-Gorski Kotar County

Frequently asked questions

  • How often is Legionella tested?

    There is no single frequency set for all buildings. For each one, it is set by its own risk assessment.

  • Is water quality tested too?

    Yes. Along with Legionella, we test the water quality parameters (group A), as for drinking water.

    Drinking water testing
  • What is tested for an occupancy permit?

    For new builds and renovations, at the technical inspection: group A and hydrocarbons (C10–C40).

Book a sampling visit