CZMV – Centar za monitoring vode+385 91 347 63 41
Contract partner of NZZJZPGŽ

Water quality testing

Pools · Drinking water · Water systemsWe come to your site, take water samples and carry out the tests required for your property, from a pool at a holiday rental to the water systems of a hotel.

Measured on site · freshwater pool
Free chlorine
0.2 – 1.0mg/L
pH value
6.5 – 7.8
Redox potential
> 750mV

Pool at your rental? Testing is mandatory.

Pools and hot tubs at holiday accommodation count as public pools and must be tested regularly.

How often must your pool be tested?

Outdoor pool
2×a month
Indoor pool
1×a month

In addition

  • Trihalomethanes (THM)all pools1× a month
  • Staphylococcus aureussea water2× a year
  • Legionella spp. and fill waterbefore the season1× a year

What do you need tested?

The scope of testing depends on what the water is used for, the type of property and your requirements.

  • Pools and hot tubs: regular testing, and the water used to fill the pool.

    • Microbiological
    • Physico-chemical
    • Trihalomethanes (THM)Disinfection by-products formed when chlorine reacts with organic matter in the water.
    • Pseudomonas aeruginosaA bacterium that can grow in warm, damp places such as pools and hot tubs.
    • Staphylococcus aureusA bacterium from bathers' skin and mucous membranes. Pools with sea water are tested for it twice a year.
    • Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols.
    Sampling water at the edge of a pool: an equipment bag and sample bottlesSampling at the pool
  • Tap water, just as people actually drink it. For homes, residential buildings, apartments, restaurants and business premises.

    • Microbiological
    • Physico-chemical
    • As required by use and regulations
    Preparing a drinking water sample at a kitchen sinkSample from the tap
  • Hot and cold water systems in buildings.

    • Water quality
    • Legionella spp.Bacteria that multiply in hot water systems and can be passed on by breathing in aerosols.
    A tidy plant room with pumps, a filter, pipes and tanksPlant room

On site

We take every sample by hand, at your pool

You get a test report for every sample

For each parameter, the report gives the test method, the maximum permitted value, the result and an assessment of compliance with the regulations.

Pool waterFreshwater pool
ParameterMaximum allowable concentrationThe limit a regulation sets for each parameter. The report gives it next to every result.
At the sampling point
Water temperatureStandard Methods 2550 Bno MAC set
Free chlorineThe part of the chlorine in the water that is available for disinfection. Measured at the sampling point.HRN EN ISO 7393-2:20180.2 – 1.0 mg/L
pH valueHow acidic or alkaline the water is, from 0 to 14 (7 is neutral). It affects how well chlorine disinfects.HRN EN ISO 10523:20126.5 – 7.8
Redox potentialAn indicator of the water's oxidising, or disinfecting, capacity. Expressed in millivolts (mV).Standard Methods 2580 B> 750 mV
TurbidityHRN EN ISO 7027-1:20161.0 NTU
Laboratory
Escherichia coliA gut bacterium: in water it means faecal contamination. Safe water has none.HRN EN ISO 9308-10 / 100 mL
Pseudomonas aeruginosaA bacterium that can grow in warm, damp places such as pools and hot tubs.HRN EN ISO 16266:20080 / 100 mL

MAC: maximum allowable concentration under the Croatian regulations on pool water (NN 59/20, 89/22)

Contract partnerTeaching Institute of Public Healthof Primorje-Gorski Kotar County

Our clients

From private holiday hosts to hotels, developers and building managers.

The journey of a sample

Tap a step
  1. Step 01

    Booking a visit

    Call or e-mail us and we'll agree on a date for sampling.

  2. Step 02

    Sampling on site

    We take the sample where the water is used. For pool water, we measure temperature, free chlorine, pH, redox potential and turbidity on site.

  3. Step 03

    Delivery to the lab

    We bring the samples in a cool bag to the NZZJZPGŽ laboratory, where they are tested for physico-chemical and microbiological parameters.

  4. Step 04

    Test report

    You receive a report with the results and an assessment of compliance with the regulations.

Book a sampling visit

+385 91 347 63 41info@czmv.hr
Contact person
Linda Petrović
Phone
+385 91 347 63 41
E-mail
info@czmv.hr
Office
Žegoti 36, 51215 Kastav